GDO-7v2 SecuraLift® Owner Installation Instructions
Operating Controls
P.E. Shunt. The shunt has to be removed when connecting a Photo Electric Beam.
NOTE: P.E. Shunt must only be removed when P.E. Beams are being connected, otherwise the opener will
malfunction. PROG INPUT is used to connect of the Automatic Technology Handheld Programmer for the
purpose of editing control and receiver functions.
Terminal Block. 24V PWR is used to power devices such as:
PE (Input) for photo electric beam for safety and auto-close function.
LGT (Input) allow hard wired external trigger for the opener’s courtesy light.
O/S/C INPUT is used for the connection of a wired switch (momentary contact). This switch can then
be used to open, stop or close the door. Install the wall switch in a location where the switch is out of
reach of children and the garage door is visible.
SET button (yellow) is used during the installation phase together with the Open and Close buttons to set
the door limit positions. The Set button is also used to re-initialize the Opener.
OPERATE button (Yellow) is used during installation to test the open, stop and close cycles for the
opener. The opener has to be initialised by the Reset button to make the O/S/C button operable.
PLUS (+) button (green) is used during installation to help set the open limit position. Pressing and
holding this button will move the door in the open direction, releasing stops the door.
NOTE: The safety obstruction detection is inoperable when the PLUS (+) button is used to move door.
OPEN LIMIT LED (green) the LED is very helpful during installation. It illuminates and fl ashes when the
door is opening and remains steady on when the open limit position has been reached.
FORCE MARGIN SET Button The obstruction force margin is set automatically during installation. The
margin can be adjusted manually using the Force Margin Set button (White). Holding the Force Margin Set
button and pressing Plus (+) or Minus (-) buttons will increase or decrease the amount of force. The Force
Margin Set should only be used if environmental factors (wind, etc.) affect the door’s operation.
LIGHT CODE button (white) is used for storing or erasing the transmitter button (code) you wish to use
to switch the courtesy light on the opener on or off.
CODING LED (red) light fl ashes when a code is being stored or when a transmitter button is pressed.
DOOR CODE BUTTON (blue) is used for storing or erasing the transmitter button you wish to use to
command the door to open, stop or close.
DOOR STATUS LED (Yellow)
MINUS (-) button (red) is used during installation to help set the close limit position. Pressing and holding
this button will move the door in the close direction. Movement stops when the button is released.
NOTE: The safety obstruction detection is inoperable when the MINUS (-) button is used to move door..
CLOSE LIMIT LED (red) the LED is very helpful during installation. It illuminates and fl ashes when the
door is closing and remains steady on when the close limit position has been reached.
Datum adjust screw is used during limits set up to indicate the mid point of the door’s travel.
AUTO CLOSE TIME button (White) is used to adjust the auto close time. While holding in the AUTO
CLOSE TIME button and then pressing the open button the time is increased. Each press will increase the
time by 5 seconds. Pressing the close button will decrease the time.
01
02
03
04
05
06
07
08
09
10
11
12
14
13
15